Portable sampler GLS

Application Areas

, ,

Producer

SKU a3c65c297427 Category

Designed for general use

The Teledyne ISCO GLS portable sampler is designed for general purpose or priority sampling of pollutants. In both municipal and industrial applications where a full-size sampler is too large. It collects composite samples based on time or flow intervals, in 1- or 2.5-gallon glass or polyethylene bottles or in disposable ProPak® bags.

Find further information further down the page or call +45 42 42 50 80.

Description

Portable sampler GLS is designed for general use

The Teledyne ISCO GLS portable sampler is designed for general purpose or priority sampling of pollutants. In both municipal and industrial applications where a full-size sampler is too large. It collects composite samples based on time or flow intervals, in 1- or 2.5-gallon glass or polyethylene bottles or in disposable ProPak® bags.

With GLS’s simplified programming, installation takes less than a minute. In the field, the operator calls up the program with two keystrokes. Presses the “go” button – and the sampling routine begins. You can also enter an alternative program in the field without losing your stored program.

​​​​​​​​​​​​​GLS Sampler
Size (Diam. x Height): 16.5 x 26.5 inches (42 x 67 cm)
Weight: 24.5 lbs (11.1 kg) (dry, less battery)
Sample bottles: 1.0 or 2.5 gallon polyethylene or glass container.
Power Requirements: 12 volts DC. (Supplied by battery or AC power converter.)
Pump
Intake purge: Purge before and after each sample.
Tubing life indicator: Provides a message to change pump tubing.
Intake suction tubing: Length 3 to 99 ft. (1 to 30 m), Vinyl or Teflon® lined, ID 0.375 in. or 0.250 in
Pump tubing life: 2,000 samples
Typical repeatability: ±10 ml
Maximum lift: 26 ft. (7.9 m)
Typical line velocity @ Head height: 2.9 ft./s @ 3 ft; 2.5 ft./s @ 10 ft; 1.9 ft./s @ 15 ft. (0.76 m/s @ 0.9 m; 0.76 m/s @ 3.1 m; 0.58 m/s @ 4.6 m)
Sample presence detector: Non-wetted, non-conductive sensor detects when liquid sample reaches the pump to automatically compensate for changes in head heights.
Operational Temperature: 32° to 120°F (0° to 49°C)
Controller
Enclosure: NEMA 4X, 6 IP67
Program storage: 1 sampling program (in non-volatile ROM)
Flowmeter signal input: 5 to 15 volt DC pulse or 25 millisecond contact closure.
Number of composite samples: Up to 500 maximum
Clock accuracy: 1 minute per month, typical, for Real Time Clock
Sampling modes: Uniform time, flow. (Flow mode is controlled by external flow meter pulses.)
Sample frequency: 1 minute to 9,999 minutes, in 1 minute increments. 1 to 9,999 flow pulses.
Sample volumes: Programmable 10 to 9,990 ml in 1 ml increments
Controller diagnostics: Tests for RAM, ROM, pump, and display

Data sheet: here