Portable flow measurement for open canals 2150

Application Areas

, ,

Producer

SKU d9d4f495e875 Categories ,

Portable flow measurement for open canals 2150 from Teledyne Isco with the option of remote reading. Large range of accessories makes the 2150 usable in many applications, including direct connection to a sampler. Up to 4 months of operation on batteries incl. Modem operation. Waterproof (IP68). Withstands immersion for 24 hours. Built-in data logger for 65,000 data sets with event-controlled log intervals.

Find further information further down the page or call +45 42 42 50 80.

Description

Portable flow measurement for open canals, sewers and streams

Portable flow measurement for open canals 2150 from Teledyne Isco with the option of remote reading. Large range of accessories makes the 2150 usable in many applications, including direct connection to a sampler. Up to 4 months of operation on batteries incl. Modem operation. Waterproof (IP68). Withstands immersion for 24 hours. Built-in data logger for 65,000 data sets with event-controlled log intervals.

Modules for 2150:

  • 2103 GSM modem
  • 2105 connection of SDI-12 sensors sample recorders and built-in GSM module
  • 2108 3 x Analog Output Module
  • Isco ProHanger Mounting Bracket
  • Isco “Street level” Assembly tool
​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​2150 Flow Module
Size (HxWxD): 2.9 x 11.3 x 7.5 in (74 x 287 x 191 mm)
Weight: 2.0 lb (0.9 kg)
Materials of construction: High-impact polystyrene, stainless steel
Enclosure (self-certified): NEMA 4X, 6P (IP68)
Temperature Range: -40° to 140° F (-40° to 60° C) operating and storage
Power Required: 12 VDC nominal (7.0 to 16.6 VDC), 100 mA typical, 1 mA standby
Power Source: Typically, a Teledyne Isco 2191 Battery Module, containing 2 alkaline or 2 rechargeable lead-acid batteries. (Other power options are available; ask for details.)
Typical Battery Life: (using 15-minute data storage interval) Energizer® Model 529 alkaline – 15 months; Teledyne Isco rechargeable lead-acid – 2.5 months
Program Memory: Non-volatile programmable flash; can be updated using PC without opening enclosure; retains user program after updating.
Built-in Conversions
Flow Rate Conversions: Up to 2 independent level-to-area conversions and/or level-to-flow rate conversions.
Level-to-Area Conversions: Channel Shapes – round, U-shaped, rectangular, trapezoidal, elliptical, with silt correction; Data Points – Up to 50 level-area points.
Level-to-Flow Conversions: Most common weirs and flumes; Manning Formula; Data Points (up to 50 level-flow points); 2-term polynomial equation
Total Flow Calculations: Up to 2 independent, net, positive or negative, based on either flow rate conversion
Data Handling and Communications
Data Storage: Non-volatile flash; retains stored data during program updates. Capacity 395,000 bytes (up to 79,000 readings, equal to over 270 days of level and velocity readings at 15-minute intervals, plus total flow and input voltage readings at 24-hour intervals)
Data Types: Level, velocity, flow rate 1, flow rate 2, total flow 1, total flow 2, input voltage, temperature
Storage Mode: Rollover; 5 bytes per reading.
Storage Interval: 15 or 30 seconds; 1, 2, 5, 15, or 30 minutes; or 1, 2, 4, 12, or 24 hours; Storage rate variable based on level, velocity, flow rate, total flow, or input voltage
Data Retrieval: Serial connection to PC or optional 2101 Field Wizard module; optional modules for spread spectrum radio; land-line or cellular modem; 1xRTT. Modbus and 4-20 mA analog available.
Software: Teledyne Isco Flowlink for setup, data retrieval, editing, analysis, and reporting
Multi-module networking: Up to four 2100 Series Flow Modules, stacked and/or remotely connected. Max distance between modules 3300 ft (1000 m).
Serial Communication Speed: 38,400 bps
2150 Area Velocity Sensor
Size (HxWxD): 0.75 x 1.3 x 6.0 in (19 x 33 x 152 mm)
Cable (Length x Diameter): 33 ft x 0.37 in (10 m x 9 mm) standard. Custom lengths available on request.
Weight (including cable): 2.2 lbs (1 kg)
Materials of construction: Sensor – Epoxy, chlorinated polyvinyl chloride (CPVC), stainless steel; Cable – Polyvinyl chloride (PVC), chlorinated polyvinyl chloride (CPVC)
Operating Temperature: 32° to 140° F (0° to 60° C)
Level Measurement
Method: Submerged pressure transducer mounted in the flow stream
Transducer Type: Differential linear integrated circuit pressure transducer
Range: Standard: 0.033 to 10 ft (0.010 to 3.05 m)
Optional: up to 30 ft (9.15 m)
Maximum Allowable Level: 34 ft (10.5 m)
Accuracy: ±0.01 ft from 0.033 to 10 ft (±0.003 m from 0.01 to 3.05 m)
Long-Term Stability: ±0.023 ft/yr (±0.007 m/yr)
Compensated Range: 32° to 122°F (0° to 50°C)
Velocity Measurement
Method: Doppler ultrasonic, frequency 500 kHz
Typical Minimum Depth: 0.08 ft (25 mm)
Range: -5 to +20 ft/s (-1.5 to +6.1 m/s)
Accuracy: (in water with uniform velocity profile, speed of sound = 4,850 ft/s, for indicated velocity range); ±0.1 ft/s from -5 to 5 ft/s (±0.03 m/s from -1.5 to +1.5 m/s); ±2% of reading from 5 to 20 ft/s (1.5 to 6.1 m/s)
Temperature Measurement
Accuracy: ±3.6° F (±2° C)
2191 Battery Module
Size (HxWxD): 6.0 x 9.6 x 7.6 in (152 x 244 x 193 mm)
Weight (without batteries): 3.2 lb (1.4 kg)
Materials of construction: High-impact polystyrene, stainless steel
Enclosure (self certified): NEMA 4X, 6P, (IP68)
Batteries: Two 6-volt Energizer Model 529* alkaline (25 Ahrs capacity) or Teledyne Isco Rechargeable Lead-acid (5 Ahrs capacity) recommended. *Note – Energizer 529 ER does not give specified life.

Data sheet: here

Manual: here

Additional information

Application Areas

, ,

Producer

Related products
Contact Aquasense

Fill out the form and we will get back to you as soon as possible.